![]() ![]() Is the main clearly marked as “MAIN BREAKER”?.Does the sum of the amperages of the main breaker and the one beside it come to equal or less than the “maximum amps per stab” listed on the manufacturer’s data plate?Įven a electric panel with a regular main breaker may be backfed by a breaker below it that is used for connecting a generator to the panel for use during a power outage.Has the breaker been mechanically secured in place?. There are specific safety requirements for this type of backfeed, and they are intended to eliminate the possiblity of the both the main breaker and the generator backfeed breaker are on the same time. ![]() See our blog post Why did my generator hookup get tagged as defective by the home inspector? for more.